R3267 Series Spectrum Analyzer Operation Manual (Vol.1)
3.3.20 SAVE Key (Saving Data)
3-66
Data Format
Sets the data format for saving data.
Setup
Used to set whether or not the measurement conditions are saved.
OFF:
Used when the measurement conditions are not saved.
ON:
Used when the measurement conditions are saved.
Trace
Used to control how the trace is saved.
OFF:
Does not save the trace data.
A:
Saves the trace data to memory A.
B:
Saves the trace data to memory B.
A/B:
Saves the trace data to memory A and memory B.
Normalize
Used to control how normalization data is saved.
OFF:
Does not save the normalization data.
A:
Saves the normalization data for trace A.
B:
Saves the normalization data for trace B.
A/B:
Saves the normalization data for trace A and trace B.
Limit Line
Used to control how Limit Line conditions are saved.
OFF:
Does not save the current values.
1:
Saves the current values for Limit Line 1.
2:
Saves the current values for Limit Line 2.
1/2:
Saves the current values for both Limit Line 1 and 2.