![ADVANTEST R3267 series Operation Manual Download Page 123](http://html1.mh-extra.com/html/advantest/r3267-series/r3267-series_operation-manual_2858766123.webp)
R3267 Series Spectrum Analyzer Operation Manual (Vol.1)
2.3.5 Measuring the Occupied Bandwidth (OBW)
2-86
Measuring the OBW
13. Press UTIL and OBW.
An occupied bandwidth at an occupancy ratio of 99% is calculated on a sweep
basis. When the measurement has been completed, width (occupied bandwidth)
and center (carrier frequency (Fc: the center of the occupied bandwidth)) are dis-
played, and two markers are placed at either end of the occupied bandwidth.
Changing the ratio to the total power
14. Press OBW%, 9, 9, ., 5 and Hz(ENTR).
The occupancy ratio is changed to 99.5%.
After the sweep, the measurement results are displayed.
Figure 2-94 OBW Measurement Results