Mode change after a change on the FlexPendant
If the remote control enable signal is active and the operator changes operating
mode on the FlexPendant, then the remote control enable signal is deactivated
internally.
The deactivation is present until the remote control enable signal has been set to
active again (toggled).
xx1700000468
A The enable signal must be toggled after a mode change on the FlexPendant.
Error handling
•
If the PLC requests a mode change when the remote control enable signal
is not active, then an event log is issued and the mode remains unchanged.
•
If the requested operating mode differs from the actual mode then robot
motion is prevented.
•
If the PLC requests a mode change to automatic mode but does not
acknowledges it within 10 seconds, then the system is set to manual reduced
speed mode and an event log is issued.
70
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
3 Installation
3.4.2 Timing and error handling
Continued