3.4.2 Timing and error handling
Mode change to automatic mode
The robot controller will change to automatic mode when all of the following
conditions apply:
•
Automatic mode is requested
•
Remote control enable is active
•
Manual reduced speed is not requested
xx1700000465
Mode change to manual reduced speed mode
The robot controller will change to manual reduced speed mode when all of the
following conditions apply:
•
Manual reduced speed is requested
•
Remote control enable is active
xx1700000467
Continues on next page
Application manual - Functional safety and SafeMove2
69
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
3 Installation
3.4.2 Timing and error handling