3.3.5 PROFIsafe F-Host
Introduction
When using PROFIsafe F-Host, the robot controller acts as a PROFIsafe controller
(
F-Host
) and can host safe I/O devices (
F-Devices)
directly. All I/O communication
for the SafeMove functionality is done via PROFIsafe (safe PROFINET).
A RobotWare license with the options
PROFINET Controller/Device
and
PROFIsafe
F-Host&Device
is required to run PROFIsafe F-Host on the robot controller.
Limitations
•
The PROFIsafe F-Host can communicate with up to 8 safe devices, PROFIsafe
F-Device, with maximum 8 slots (modules) per device, where each slot can
have maximum 8 byte.
Install and configure safe I/O devices
For information on how to connect and configure the safe I/O devices, see
Application manual - PROFINET Controller/Device
.
Operator acknowledge
There are two ways to acknowledge a change in the PROFIsafe communication,
for example if the communication cable was disconnected and reconnected:
•
By tapping the
F-Host Op. Ack.
button in the FlexPendant user interface,
see
PROFIsafe F-Host operator acknowledge on page 115
•
By setting the system input
ProfiSafeOpAck
, see
.
66
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
3 Installation
3.3.5 PROFIsafe F-Host
Summary of Contents for SafeMove2
Page 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 72: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 196: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 237: ......