Note
Navigate to the RobotWare installation folder from the RobotStudio
Add-Ins
tab,
by right-clicking on the installed RobotWare version in the
Add-Ins
browser and
selecting
Open Package Folder
.
Clearing a pre-existing configuration
The first scanner (originator) that successfully establishes a producing connection
to the ABB CIP safety adapter becomes the owner of that adapter's inputs. It is
necessary to reset the ownership when the originator's SNN or NodeID is changed.
The ownership is established to prevent errant or unauthorized connections from
hijacking an input resource in a validated safety system. Only one owner is allowed.
It is possible to reset the ownership by executing the reset CIP Safety function
from the FlexPendant which resets all persistent memory of the adapter, see
. After controller restart, the CIP Safety configuration will be
restored except from the ownership.
Note
It is the responsibility of the user to guarantee the safety of the system after the
reset CIP Safety function has been used. The user needs to guarantee that the
desired ownership is established after the reset.
64
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
3 Installation
3.3.3 CIP Safety Adapter
Continued
Summary of Contents for SafeMove2
Page 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 72: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 196: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 237: ......