Which axes to supervise, with specified stand still measurement tolerance,
for each stand still set.
•
Set an output signal if a violation occurs.
•
Set a status signal when the function is active.
See
Configuring Stand Still Supervision on page 166
Function activation
Stand Still Supervision is activated by a safe input signal, or is permanently active
if only output signal and no stop is used.
Note
If SafeMove becomes unsynchronized, the robot will stop and the Stand Still
Supervision function will be deactivated. A movement with reduced speed is
possible.
Limitations
•
Stand Still Supervision is only available for SafeMove Pro, see
.
Application manual - Functional safety and SafeMove2
47
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
2 SafeMove functions
2.5.1 Stand Still Supervision (SST)
Continued