6.21 Restore configuration
Restore configuration from backup
When performing a system backup, a SafeMove safety configuration file is included.
This file gives the possibility to restore the SafeMove safety configuration without
changing it. The advantage is that the configuration is identical, so the SafeMove
safety configuration does not have to be validated and no new safety report has
to be generated.
The safety settings includes the safety configuration, the EIO configuration, and
the version information.
When restoring a backup, select the
Include Safety Settings
check box to also
restore the safety configuration.
Restore configuration from RobotStudio
The file can also be restored separately from the system backup by using the
Restore Configuration
function in
Visual SafeMove
.
Note/illustration
Action
Open
Visual SafeMove
.
1
xx1500000533
Click on
Controller
in the
Visual Safe-
Move
ribbon and select
Restore Config-
uration
.
2
Browse to the
BACKINFO
folder in the
backup.
3
Select the file
sc_cfg.xml
and click
Open
.
4
The
Restart Controller
dialog is shown
when the safety configuration has been
downloaded.
5
Click
Yes
to restart the controller.
186
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
6 Configuring SafeMove
6.21 Restore configuration
Summary of Contents for SafeMove2
Page 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 72: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 196: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 237: ......