![ABB IRB 390 Product Manual Download Page 219](http://html.mh-extra.com/html/abb/irb-390/irb-390_product-manual_5047219.webp)
Refitting the lower end of the telescopic shaft
Note
Action
CAUTION
The telescopic shaft must be oriented correctly,
otherwise it is damaged. Always fit the narrow
shaft part up against the base unit.
1
Cleaning agent: Isopropanol.
Clean the friction shim and sealing ring with isop-
ropanol.
2
Friction shim: 3HAC060200-001.
Inspect the friction shim and sealing ring. Replace
if damaged.
Sealing ring: 3HAC060263-001
xx1900001830
Fit the friction shim to the telescopic shaft lower
joint.
3
xx1900001826
Install the sealing ring at the lower joint and guide
the telescopic shaft into place.
CAUTION
Hold the telescopic unit carefully, the tube may
slide and get damaged.
4
Continues on next page
Product manual - IRB 390
219
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the telescopic shafts and universal joints
Continued