Removing the top cover
Note
Action
xx2000001006
Disconnect connector R1.MP from the base.
1
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
2
xx1900000407
Remove the SMB battery cover.
Tip
The battery cover is removed to see the battery
position during refitting of the top cover.
3
xx1900000469
Remove the cover by removing the screws and
washers. Also remove the sealing.
4
Continues on next page
172
Product manual - IRB 390
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the cable harness
Continued