Disconnecting the axis-1, axis-2 and axis-3 motor cabling
Note
Action
Remove the axis-1, axis-2 and axis-3 motor covers
and sealings.
1
xx2000001005
Cut required cable ties and snap loose the motor
connectors from the brackets.
Tip
Take pictures of the cable routing and placement
of cable ties, before cutting the ties.
2
Disconnect the motor connectors.
3
xx2000002199
Loosen the bracket from the motor.
4
xx2000002200
Pull out the bracket and cut the remaining cable
ties.
5
Continues on next page
Product manual - IRB 390
173
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the cable harness
Continued