![ABB IRB 390 Product Manual Download Page 178](http://html.mh-extra.com/html/abb/irb-390/irb-390_product-manual_5047178.webp)
Refitting the cable harness
Use these procedures to refit the cable harness.
Refitting the cable harness
Note
Action
Cable harness: 3HAC060469-001.
Place the new cable harness inside the base unit.
1
xx2000001030
Push through the connectors for axis-1, axis-2
and axis-3 motors to the motor units.
DANGER
Check the labels on the motor cables, to make
sure the correct cabling is routed to the correct
motor.
2
Cable ties
xx2000001025
Tie the cabling with cable ties inside the base unit.
CAUTION
Be aware of the pinch points where the cabling
passes next to the gear flanges. Route and tie the
cable to avoid pinching between the flange and
the gear unit during refitting later on.
3
xx2000002211
Reconnect the signal lamp connectors H1 and
H2.
4
xx2000001023
Reconnect the brake release connector.
5
Continues on next page
178
Product manual - IRB 390
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the cable harness
Continued