Parameters and firmware blocks
115
(2)
RELATIVE
Speed error window control active. The window boundaries set by
parameters
are only effective in the forward direction
(i.e. when actual speed is positive).
26.11
SPEED WIN HI
(see above)
High limit for speed window control. See parameter
.
0…3000 rpm
High limit for speed error window control.
26.12
SPEED WIN LO
(see above)
Low limit for speed window control. See parameter
.
0…3000 rpm
Low limit for speed error window control.