Drive control and features
48
Motor
M
230 VAC
JCU unit
Mechanical brake
Brake control
hardware
Emergency
brake
X2
1
RO1
2
RO1
3
RO1
X3
11 DI5
13 +24 V
The brake on/off is controlled via signal
3.15
. The source for the brake
supervision is selected by parameter
35.02
The brake control hardware and wirings need to be done by the user.
• Brake on/off control through selected relay/digital output.
• Brake supervision through selected digital input.
• Emergency brake switch in the brake control circuit.
• Brake on/off control through relay output (i.e. parameter
12.12
is set to P.03.15 =
3.15
• Brake supervision through digital input DI5 (i.e. parameter
35.02
P.02.01.04 =
2.01
DI STATUS