Parameters and firmware blocks
95
(512)
SET3 PAR ACT
User parameter set 3 has been loaded using parameter
(1024)
SET4 PAR ACT
User parameter set 4 has been loaded using parameter
16.11
USER IO SET LO
FW block: None
, selects the user parameter set when parameter
. The status of the source defined by this parameter and
select the user parameter set as follows:
Bit pointer: Group, index and bit
16.12
USER IO SET HI
FW block: None
See parameter
Bit pointer: Group, index and bit
16.13
TIME SOURCE PRIO
FW block: None
Selects which real-time clock source is adopted by the drive as the master real-time clock. Some
selections specify multiple sources that are in order of priority.
(0)
FB_D2D_MMI
Fieldbus (highest priority); drive-to-drive link; man-machine interface
(control panel or PC).
(1)
D2D_FB_MMI
Drive-to-drive link (highest priority); fieldbus; man-machine interface
(control panel or PC).
(2)
FB_D2D
Fieldbus (highest priority); drive-to-drive link.
(3)
D2D_FB
Drive-to-drive link (highest priority); fieldbus.
(4)
FB ONLY
Fieldbus only.
(5)
D2D ONLY
Drive-to-drive link only.
(6)
MMI_FB_D2D
Man-machine interface (control panel or PC) (highest priority);
fieldbus; drive-to-drive link.
(7)
MMI ONLY
Man-machine interface (control panel or PC) only.
(8)
INTERNAL
No external sources are used as master real-time clock.
Status of source
defined by par.
Status of source
defined by par.
User parameter set
selected
FALSE
FALSE
Set 1
TRUE
FALSE
Set 2
FALSE
TRUE
Set 3
TRUE
TRUE
Set 4
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......