Fault tracing
202
2006
EMERGENCY OFF
(0xF083)
Drive has received emergency
OFF2 command.
To restart drive, activate RUN ENABLE signal
(source selected by parameter
) and start drive.
2007
RUN ENABLE
(0xFF54)
No Run enable signal is
received.
Check setting of parameter
. Switch signal on (e.g. in the
fieldbus Control Word) or check wiring of
selected source.
2008
ID-RUN
(0xFF84)
Motor identification run is on.
This alarm belongs to normal start-up
procedure. Wait until drive indicates that
motor identification is completed.
Motor identification is required.
This alarm belongs to normal start-up
procedure.
Select how motor identification should be
performed, parameter
Start identification routines by pressing Start
key.
2009
EMERGENCY STOP
(0xF081)
Drive has received emergency
stop command (OFF1/OFF3).
Check that it is safe to continue operation.
Return emergency stop push button to normal
position (or adjust the fieldbus Control Word
accordingly).
Restart drive.
2011
BR OVERHEAT
(0x7112)
Brake resistor temperature has
exceeded alarm limit defined by
parameter
Stop drive. Let resistor cool down.
Check resistor overload protection function
settings, parameters
Check alarm limit setting, parameter
.
Check that braking cycle meets allowed
limits.
2012
BC OVERHEAT
(0x7181)
Brake chopper IGBT
temperature has exceeded
internal alarm limit.
Let chopper cool down.
Check resistor overload protection function
settings, parameters
Check that braking cycle meets allowed
limits.
Check that drive supply AC voltage is not
excessive.
2013
DEVICE OVERTEMP
(0x4210)
Measured drive temperature
has exceeded internal alarm
limit.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
2014
INTBOARD OVERTEMP
(0x7182)
Interface board (between power
unit and control unit)
temperature has exceeded
internal alarm limit.
Let drive cool down.
2015
BC MOD OVERTEMP
(0x7183)
Input bridge or brake chopper
temperature has exceeded
internal alarm limit.
Let drive cool down.
Code
Alarm
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......