Standard function blocks
231
Outputs
Output (O): INT, DINT
REG
(10038)
Illustration
Execution time
2.27 µs (when two inputs are used) + 1.02 µs (for every additional input). When all
inputs are used, the execution time is 32.87 µs.
Operation
The input (I1…I32) value is stored to the corresponding output (O1…O32) if the load
input (L) is set to 1 or the set input (S) is 1. When the load input is set to 1, the input
value is stored to the output only once. When the set input is 1, the input value is stored
to the output every time the block is executed. The set input overrides the load input.
If the reset input (R) is 1, all connected outputs are 0.
Example:
Inputs
The input data type and number of inputs (2…32) are selected by the user.
Set input (S): Boolean
Load input (L): Boolean
Reset input (R): Boolean
Input (I1…I32): Boolean, INT, DINT, REAL, REAL24
Outputs
Output (O1…O32): Boolean, INT, DINT, REAL, REAL24
REG
(BOOL)
68
TLA1 1 msec
(1)
S
>L
R
I1
I2
O1
O1(68)
O2
O2(68)
S
R
L
I
O1
previous
O1
0
0
0
10
15
15
0
0
0->1
20
15
20
0
1
0
30
20
0
0
1
0->1
40
0
0
1
0
0
50
0
50
1
0
0->1
60
50
60
1
1
0
70
60
0
1
1
0->1
80
0
0
O1
previous
is the previous cycle output value.
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......