Parameters and firmware blocks
164
(2)
WARNING
The drive generates an ENCODER 1/2 CABLE warning. This is the
recommended setting if the maximum pulse frequency of sine/cosine
incremental signals exceeds 100 kHz; at high frequencies, the signals
may attenuate enough to invoke the function. The maximum pulse
frequency can be calculated as follows:
90.10
ENC PAR REFRESH
FW block:
(see above)
Setting this parameter to 1 forces a reconfiguration of the FEN-xx interfaces, which is needed for any
parameter changes in groups 90…93 to take effect.
The parameter is read-only when the drive is running.
(0)
DONE
Refreshing done.
(1)
CONFIGURE
Reconfigure. The value will automatically revert to DONE.
Pulses per revolution (par.
) × Maximum speed in rpm
60
Summary of Contents for ACSM1 Series