![ABB ACS380 Series Firmware Manual Download Page 477](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560477.webp)
Fieldbus control through the embedded fieldbus interface (EFB) 477
608Fh 0
Highest sub-
index
supported
U8
Const
This object indicates the configured
encoder increments and number of motor
revolutions.
The position encoder resolution is
calculated by the following formula:
position encoder resolution = encoder
increments / motor revolutions
1
Encoder
Increments
U32
RW
2
Motor
Revolutions
U32
RW
60C2h 0
Highest sub-
index
supported.
U8
Const
This object indicates the interpolation
cycle time.
1
Interpolation
time period
value
U8
RW
Value of the time.
2
Interpolation
time index
INT8
RW
Dimension index to the time value in sub-
index 1
60FFh 0
Target
velocity
INT32
RWW
This object indicates the configured target
velocity.
6402h 0
Motor type
U6
RO
This object indicates the type of motor
attached to and driven by the drive device.
The following value definition is valid:
0000h = non-standard motor
0001h = phase modulated DC motor
0002h = frequency controlled DC motor
0003h = PM synchronous motor
0004h = FC synchronous motor
0005h = switched reluctance motor
0006h = wound rotor induction motor
0007h = squirrel cage induction motor
0008h = stepper motor
0009h = micro-step stepper motor
0010h = sinusoidal PM BL motor
0011h = trapezoidal PM BL motor
0012h = AC synchronous reluctance sync
0013h = DC commutator PM
0014h = DC commutator wound field
series
0015h = DC commutator wound field
compound
7FFFh = no motor type assigned
8000h-FFFFh = manufacturer-specific
Index
Sub-
index
Name
Type
Access Description
ACS380 FW.book Page 477 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |
www.ghv.de