![ABB ACS380 Series Firmware Manual Download Page 283](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560283.webp)
Parameters 283
Timed function 3
Bit 2 of
34.01 Timed functions status
.
20
Supervision 1
Bit 0 of
32.01 Supervision status
21
Supervision 2
Bit 1 of
32.01 Supervision status
22
Supervision 3
Bit 2 of
32.01 Supervision status
.
23
Supervision 4
Bit 3 of
32.01 Supervision status
.
24
Supervision 5
Bit 4 of
32.01 Supervision status
.
25
Supervision 6
Bit 5 of
32.01 Supervision status
.
26
Other [bit]
Source selection (see
Terms and abbreviations
on page
112
).
-
44.203 Torque proving
reference
Defines the Torque proving (electrical test) reference to be
used when the Torque proving function is enabled.
25.0%
0.0 … 300.0%
Torque proving (electrical test) reference in percentage of
the motor nominal torque (
01.10
Motor torque
).
1 = 1%
44.204 Brake system check
time
Defines the time delay during which Torque proving is
active and the electrical and mechanical tests of the crane
system are done against a closed brake. If the actual
torque cannot be reached during this check time, he drive
trips on fault
D100
Torque prove
.
0.30 s
0.10….30.00 s
Time delay.
1000 = 1 s
44.205 Brake slip speed limit
Defines the speed limit used for examining the system for
brake slips during Torque proving (mechanical test). For
more information on the function, see section
Brake
system checks – Brake slip
on page
537
.
30.00 rpm
0.00 … 30000.00 rpm
Brake slip speed limit.
1 = 1 rpm
44.206 Brake slip fault delay
Defines the time delay before the drive trips on fault
D101
Brake slip
during Torque proving (mechanical test).
If a brake slip is detected during the system check time
(
44.204
Brake system check time
), the fault is generated
immediately, even if the check time had not yet elapsed.
300 ms
0…30000 ms
Time delay.
1 = 1 ms
44.207 Safety close select
Selects whether the Brake safe closure function is active
or not. For more information on the function, see section
Brake safe closure
on page
538
.
Not selected
Not selected
Brake safe closure function is inactive.
0
Selected
Brake safe closure function is active.
1
DI1
Digital input DI1 (
10.02
DI delayed status
, bit 0).
2
DI2
Digital input DI2 (
10.02
DI delayed status
, bit 1).
3
DI3
Digital input DI3 (
10.02
DI delayed status
, bit 2).
4
DI4
Digital input DI4 (
10.02
DI delayed status
, bit 3).
5
DIO1
Digital input/output DIO1 (
11.02
DIO delayed status
, bit 0). 10
DIO2
Digital input/output DIO2 (
11.02
DIO delayed status
, bit 1) 11
Timed function 1
Bit 0 of
34.01 Timed functions status
.
18
Timed function 2
Bit 1 of
34.01 Timed functions status
.
19
Timed function 3
Bit 2 of
34.01 Timed functions status
.
20
Supervision 1
Bit 0 of
32.01 Supervision status
24
Supervision 2
Bit 1 of
32.01 Supervision status
25
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 283 Friday, May 4, 2018 4:18 PM
ghv Vertriebs-GmbH
| Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |