Parameters 303
58.05
Parity
Selects the type of parity bit and number of stop bits.
Changes to this parameter take effect after the control unit
is rebooted or the new settings validated by parameter
58.06
Communication control
(
Refresh settings
).
Note
: If parameter
58.01
= [3] CANopen, this parameter is
hidden.
8 EVEN 1
8 NONE 1
Eight data bits, no parity bit, one stop bit.
0
8 NONE 2
Eight data bits, no parity bit, two stop bits.
1
8 EVEN 1
Eight data bits, even parity bit, one stop bit.
2
8 ODD 1
Eight data bits, odd parity bit, one stop bit.
3
58.06
Communication
control
Takes changed EFB settings in use, or activates silent
mode.
Enabled
Enabled
Normal operation.
0
Refresh settings
Refreshes settings (Modbus parameters
58.01
…
58.05
,
58.14
…
58.17
,
58.25
,
58.28
…
58.34
, CANopen
parameters
58.03
,
58.04
,
58.06
,
58.14
,
58.23
...
58.29
,
58.70
...
58.93
and
58.101
...
58.124
) and takes changed
EFB configuration settings in use.
Reverts automatically to
Enabled
.
1
Silent mode
Activates silent mode (no messages are transmitted).
Silent mode can be terminated by activating the
Refresh
settings
selection of this parameter.
Note
: If parameter
58.01
= [3] CANopen, this option is not
available.
2
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 303 Friday, May 4, 2018 4:18 PM