![ABB ACS380 Series Firmware Manual Download Page 353](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560353.webp)
Parameters 353
99.16
Motor phase order
Switches the rotation direction of motor. This parameter
can be used if the motor turns in the wrong direction (for
example, because of the wrong phase order in the motor
cable), and correcting the cabling is considered
impractical.
Notes:
• Changing this parameter does not affect speed
reference polarities, so positive speed reference will
rotate the motor forward. The phase order selection just
ensures that “forward” is in fact the correct direction.
U V W
U V W
Normal.
0
U W V
Reversed rotation direction.
1
No.
Name/Value
Description
Default
FbEq 16
ACS380 FW.book Page 353 Friday, May 4, 2018 4:18 PM