Parameters 285
45.02
Saved MW hours
Energy saved in MWh compared to direct-on-line motor
connection. This parameter is incremented when
45.03
Saved kW hours
rolls over.
When this parameter rolls over, parameter
45.01
Saved
GW hours
is incremented.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0…999 MWh
Energy savings in MWh.
1 = 1 MWh
45.03
Saved kW hours
Energy saved in kWh compared to direct-on-line motor
connection.
If the internal brake chopper of the drive is enabled, all
energy fed by the motor to the drive is assumed to be
converted into heat, but the calculation still records
savings made by controlling the speed. If the chopper is
disabled, then regenerated energy from the motor is also
recorded here.
When this parameter rolls over, parameter
45.02
Saved
MW hours
is incremented.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0.0…999.9 kWh
Energy savings in kWh.
10 = 1 kWh
45.04
Saved energy
Energy saved in kWh compared to direct-on-line motor
connection.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0.0…214748364.7
kWh
Energy savings in kWh.
1 = 1 kWh
45.05
Saved money x1000
Monetary savings in thousands compared to direct-on-line
motor connection. This parameter is incremented when
45.06
Saved money
rolls over.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0…4294967295
thousands
Monetary savings in thousands of units.
1 = 1 unit
45.06
Saved money
Monetary savings compared to direct-on-line motor
connection. This value is a calculated by multiplying the
saved energy in kWh by the currently active energy tariff
(
45.14
Tariff selection
).
When this parameter rolls over, parameter
45.05
Saved
money x1000
is incremented.
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0.00…999.99 units
Monetary savings.
1 = 1 unit
45.07
Saved amount
Monetary savings compared to direct-on-line motor
connection. This value is a calculated by multiplying the
saved energy in kWh by the currently active energy tariff
(
45.14
Tariff selection
).
This parameter is read-only (see parameter
45.21
Energy
calculations reset
).
-
0.00… 21474836.47
units
Monetary savings.
1 = 1 unit