Program features 103
Local control loss detection (parameter
49.05
)
The parameter selects how the drive reacts to a control panel or PC tool
communication break.
AI supervision (parameters
12.03
…
12.04
)
The parameters select how the drive reacts when an analog input signal moves out of
the minimum and/or maximum limits specified for the input.
Automatic fault resets
The drive can automatically reset itself after overcurrent, overvoltage, undervoltage
and external faults. The user can also specify a fault that is automatically reset.
By default, automatic resets are off and must be specifically activated by the user.
Settings
Parameters
31.12
…
31.16
.