![ABB ACS380 Series Firmware Manual Download Page 189](http://html.mh-extra.com/html/abb/acs380-series/acs380-series_firmware-manual_2560189.webp)
Parameters 189
Selected
Increases the motor potentiometer value depending on
the selected direction. The possible effect can be seen in
parameter
22.225
Crane motpot sw
, bits 3 and 4.
1
DI1
Digital input DI1 (
10.02
DI delayed status
, bit 0).
2
DI2
Digital input DI2 (
10.02
DI delayed status
, bit 1).
3
DI3
Digital input DI3 (
10.02
DI delayed status
, bit 2).
4
DI4
Digital input DI4 (
10.02
DI delayed status
, bit 3).
5
DIO1
Digital input/output DIO1 (
11.02
DIO delayed status
, bit 0) 10
DIO2
Digital input/output DIO2 (
11.02
DIO delayed status
, bit 0) 11
Timed function 1
Bit 0 of
34.01 Timed functions status
.
18
Timed function 2
Bit 1 of
34.01 Timed functions status
.
19
Timed function 3
Bit 2 of
34.01 Timed functions status
.
20
Supervision 1
Bit 0 of
32.01 Supervision status
.
24
Supervision 2
Bit 1 of
32.01 Supervision status
.
25
Supervision 3
Bit 2 of
32.01 Supervision status
.
26
Supervision 4
Bit 3 of
32.01 Supervision status
.
27
Supervision 5
Bit 4 of
32.01 Supervision status
.
28
Supervision 6
Bit 5 of
32.01 Supervision status
.
29
Other [bit]
Source selection (see
Terms and abbreviations
on page
112
).
-
22.224 Crane motpot min
speed
Defines an initial value (starting point) for the motor
potentiometer at start. See section
Crane motor
potentiometer
on page
557
.
0.00
0.00...30000
Minimum speed.
1 = 1
22.225 Crane motpot sw
Crane motor potentiometer status word.
0000h
0000h...FFFFh
Status word.
1 = 1
22.226 Crane motpot min
value
Defines the minimum value of the Crane motor
potentiometer.
-50.00
-30000.00...
30000.00
Minimum value
1= 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Crane motpot
enabled
Status of the Crane motor potentiometer function.
1 = Crane motor potentiometer enabled.
0 = Crane motor potentiometer disabled.
1...2
Reserved
3
Crane motpot
up source
Used as source for four inputs of the motor potentiometer to increase
the output value.
1 = Crane motor potentiometer with increased output reference.
0 = Crane motor potentiometer without increased output reference.
4
Crane motpot
dn source
Used as source for four inputs of the motor potentiometer to decrease
the output value.
1 = Crane motor potentiometer with decreased output reference.
0 = Crane motor potentiometer without decreased output reference.
5…15
Reserved
ACS380 FW.book Page 189 Friday, May 4, 2018 4:18 PM