Note
Action
xx1800003030
Reconnect the connectors.
•
J2.FB2,3,4,5,6
•
J2.MP3,4,5/6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (2 pcs)
Refit the connector plate.
4
Tightening torque: 0.8 Nm
xx1800002489
Refitting the swing covers
Note
Action
Apply grease to the cable package, cover all
moving area of the package.
1
Apply grease to the covers that have contacting
area with the cable package.
2
Continues on next page
Product manual - IRB 1100
499
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued