Note
Action
Used belt: 81.3-86.9 Hz
Use an acoustic tensiometer to measure the tim-
ing belt tension.
8
New belt:90-114 Hz (for reference
only)
If the timing belt tension does not meet the require-
ment, loosen the motor screws and readjust.
9
xx1900000007
Remove the adjustment screw from the motor.
10
Reconnecting the axis-6 motor connectors
Note
Action
xx1800002994
Reconnect the connectors.
•
FB6
•
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Continues on next page
386
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the extender unit and wrist
Continued