Note
Action
Tightening torque: 0.3 Nm
Reconnect the connectors.
2
xx1800002468
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (6 pcs)
Refit the SMB cover to the base.
4
Tightening torque: 1.2 Nm
xx1800002467
Continues on next page
Product manual - IRB 1100
223
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued