Note
Action
xx1800003031
Valid for IRB 1100-4/0.475
Access the cable package locking screw on the
axis-4 gearbox from the wrist and then loosen the
locking screw.
2
xx1800003000
Valid for IRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
3
xx1800003001
Disconnecting the axis-4 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
318
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued