Securing the lower cable package to the base
Note
Action
Screw: M2.5x6 12.9 Gleitmo
603+Geomet 500 (2 pcs)
Refit the cable bracket.
1
Tightening torque: 0.6 Nm
xx1800003042
Reconnecting the brake release cabling and axis-1 motor connectors
Note
Action
xx1800003054
Reconnect the connectors.
•
J1M.BR
•
MP1
•
FB1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Continues on next page
224
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued