112
Fig. 89. Circuit Diagram for Check of Rectifying Unit:
a - checking of «plus» diodes; b - checking of «minus» diodes; I - diodes are connected
for non-conducting; II - diodes are connected for conducting
Mind, that the rectifying unit diodes in good working order conduct current in
one direction only, consequently, the lamp is on, only if the diodes are connected in
the conducting direction. If the pilot lamp is switched on in both directions and in
both cases it goes ON or OFF, it means that the rectifying unit diodes are faulty. If
any fault of diodes is discovered, replace the rectifying unit.
Do not test the rectifying unit connected to:
- a voltage source of more than 24 V;
- an a.c. source.
Fig.88. Circuit Diagram for
Bench Test of Alternator
Electric Parameters:
1 - alternator; 2 - current
indicator; 3 - voltmeter; 4 -
load; 5 - storage battery; 6 -
ballast resistor