The Service Mode screen is used to turn the service mode on or off.
Turning service mode “ON” locks out any remote actions and allows
access to parameters and functions that are useful when making
adjustments or diagnosing the Model 5028
i
. The service (wrench)
icon on the status bar is shown when service mode is on. For more
information about the service mode, see “
chapter.
Note
The service mode should be turned off when finished, as it
prevents remote operation.
s
l
In the Main Menu, choose Instrument Controls >
Service Mode
.
SERVICE MODE:
CURRENTLY: OFF
SET TO: ON ?
TOGGLE VALUE
RANGE AVG DIAGS ALARM
The Date/Time screen allows the user to view and change the system
date and time (24-hour format). The internal clock is powered by its
own battery when instrument power is off.
l
In the Main Menu, choose Instrument Controls >
Date/Time
.
DATE AND TIME:
19 MAR 2005 12:34:56
PRESS TO EDIT
RANGE AVG DIAGS ALARM
DATE AND TIME:
19 MAR 2005 12:34:56 ?
SETTING: DAYS
SET MONTHS
CHANGE VALUE
SAVE VALUE
RANGE AVG DIAGS ALARM
The Timezone screen is used to set the timezone for the Network Time
Protocol (NTP) server. This should be set to the timezone that the
instrument is located in. If the exact timezone is not shown in the list,
it may be entered via the C-LINK “tz” command (see Appendix B).
The selections are: UTC (GMT), EST (GMT+5), CST (GMT+6),
MST (GMT+7), PST (GMT+8), YST (GMT+9), HST (GMT+10),
NST (GMT+11), DLW (GMT+12), CET (GMT-1), EET (GMT-
2), BST (GMT-3), DLT (GMT-4), ECH (GMT-5), FOX (GMT-6),
GLF (GMT-7), CCT (GMT-8), JST (GMT-9), GST (GMT-10), LMA
(GMT-11), DLE (GMT-12), EDT (GMT+5/4), CDT (GMT+6/5),
MDT (GMT+7/6), and PDT (GMT+8/7).
Service Mode
Date/Time
Timezone
Содержание 5028i
Страница 1: ...Model 5028i Instruction Manual Continuous Particulate Monitor CIC0001582 April 2018...
Страница 2: ......
Страница 3: ...Model 5028i Instruction Manual Continuous Particulate Monitor Part Number CIC0001582 8Apr2018...
Страница 6: ...WEEE Compliance Thermo Fisher Scientific...
Страница 12: ...About This Manual WEEE Symbol vi Model 5028i Instruction Manual Thermo Fisher Scientific...
Страница 36: ......
Страница 142: ......
Страница 154: ......
Страница 220: ......
Страница 222: ...System Description Hardware 8 2 Model 5028i Instruction Manual Thermo Fisher Scientific Figure 8 1 Hardware Components...
Страница 232: ......
Страница 328: ......
Страница 329: ......