Advanced Operations using the Flash Controller
541
SLAU356I – March 2015 – Revised June 2019
Copyright © 2015–2019, Texas Instruments Incorporated
Flash Controller A (FLCTL_A)
•
Any read, program, or erase operation currently being serviced continues.
•
Outstanding flash operations are processed normally.
•
New accesses or operations are processed normally.
10.3.7.2 Hard Reset or POR Reset (Class 2)
A hard reset has the following effects on flash controller functionality:
•
All current and outstanding read operations are terminated.
•
All current and outstanding program or erase operations are terminated.
•
All application settings in the flash control registers are reset.