23.3.1 CExCTL0 Register (offset = 00h) [reset = 0000h]
Comparator_E Control Register 0
Figure 23-8. CExCTL0 Register
15
14
13
12
11
10
9
8
CEIMEN
Reserved
CEIMSEL
rw-0
r-0
r-0
r-0
rw-0
rw-0
rw-0
rw-0
7
6
5
4
3
2
1
0
CEIPEN
Reserved
CEIPSEL
rw-0
r-0
r-0
r-0
rw-0
rw-0
rw-0
rw-0
Table 23-2. CExCTL0 Register Description
Bit
Field
Type
Reset
Description
15
CEIMEN
RW
0h
Channel input enable for the V- terminal of the comparator.
0b = Selected analog input channel for V- terminal is disabled.
1b = Selected analog input channel for V- terminal is enabled.
14-12
Reserved
R
0h
Reserved. Always reads as 0.
11-8
CEIMSEL
RW
0h
Channel input selected for the V- terminal of the comparator if CEIMEN is set to
1.
7
CEIPEN
RW
0h
Channel input enable for the V+ terminal of the comparator.
0b = Selected analog input channel for V+ terminal is disabled.
1b = Selected analog input channel for V+ terminal is enabled.
6-4
Reserved
R
0h
Reserved. Always reads as 0.
3-0
CEIPSEL
RW
0h
Channel input selected for the V+ terminal of the comparator if CEIPEN is set to
1.