NSG 3040 EMC test system
10 COUPLING NETWORK CDN 3041
Parameter
Value
Instrument supply:
85...265 VAC
Decoupling attenuation:
Remanent pulse 15% max.
Mains side crosstalk 15% max.
Standard-conform pulse:
1.2/50 μs up to 4.4 kV
8/20 μs up to 2.2 kA
Mains decoupling:
1.5 mH
Connections:
Pulse input(s) from generator
Cable connector for EUT supply input
and output
Power inlet for CDN
EUT supply:
1-phase (P/N/PE)
EUT VAC:
24 to 270 V rms, 50/60 Hz
(Phase - Neutral), 400 Hz max.
EUT VDC:
0 to 270 VDC
EUT current:
1 x 16 A rms continuous
over heat protected
1 x 25 A rms for 30 min
EFT (burst):
Standard coupling all lines to HF
reference ground GND
IEC/EN 61000-4-4 and ANSI (IEEE)
C62.41 L, N, PE à GND
The internal coupling network CDN 3041 is fully integrated in the NSG 3040
generator. It enables to couple the different pulses on a single phase EUT within
the limits described below.