8.5.8 Dips & interrupts technical data
Parameter
Value
Dips & Interrupts:
From EUT voltage input to 0 V; 0%
Uvar with optional variac:
up to 265 V
up to 115% of Uin
16 A max. ±10%
Uvar step transformer:
0%, 40%, 70%, 80%
Peak inrush current capability:
> 500 A (at 230 V)
Switching times:
1 to 5 μs (100 Ω load)
Phase phase synchronization:
Asynchronous, synchronous 0° to 359º
(in 1º steps)
Time rep repetition time:
µs:
40 ... 99’999
ms:
1 ... 99’999
s:
1 ... 1’999
min:
1 ... 35
cycle:
1 ... 99’999
Event time (T-Event):
µs:
20 ... 99’999
ms:
1 ... 99’999
s:
1 ... 1’999
cycle:
1 ... 300
¹⁄10 cycle:
1 ... 3000
Test duration:
s:
1 ... 99’999
min:
1 ... 70’000
pulse:
1 ... 99’999
Continuous
8.5.9 Variation test technical data
Parameter
Value
Uvar with optional variac:
up to 265 V (in 1 V steps)
up to 115% of Uin (in 1% steps)
Phase synchronization:
asynchronous, synchronous, 0° to 359°
(in 1° steps)
Repetition time:
1000 ms to 35 min.
1 to 99’999 cycles