44
NSG 3040 EMC test system
To open the NSG 3040, the user must first remove the sides panels. Each side
panel has 4 snap fixtures which will separate when outward pressure is applied.
1. Pull outward on the indentation in the front of the side panel. A blunt tool
which will not scratch the paint on the panel may be used.
2. Pull outward to separate the panel from the snap fixtures.
3. Remove the upper screws on both sides of the generator cover.
4. Remove the NSG 3040 cover. The SD-card slot is located at the right front of
the generator, in back of the front panel.
5. Press the SD-card to release it. Remove the card from the slot. To install a
new SD-card, proceed to step 7.
6. To download new software from a PC to the SD card, insert the card in the
SD port of the PC and copy the software to the SD card. The file name must
remain SUI3000AP.EXE. Remove the SD card from the PC.
7. Insert the SD-card in the NSG 3040. Follow steps 1 - 4 in reverse to replace
the generator cover and side panels.
8. Restart the NSG 3040. The new software version will boot automatically and
may be verified in the equipment detail window (see section 7.7.1).