138
NSG 3040 EMC test system
Parameter
Value
Length:
1230 mm
Width:
250 mm
Height:
170 mm
Weight:
3.5 kg approx.
Mechanical parameters INA 3825
Parameter
Value
Usable length of the clamp:
1100 mm
Diameter of the test cable:
4 to 40 mm
Connectors:
SHV-NIM female, 50 Ω on
both ends)
Distance of the earth reference plane:
100 mm
Electrical parameters of the clamp
Max. permissible burst voltage
8 kV
When used together with a burst EFT generator for more than 4 kV, it is recom-
mended to cover the CDN 3425 with the INA 3825 cover with interlock, and to
connect the foreseen interlock cable of INA 3825 to the interlock input of the
EFT/burst generator.
This way the user is protected from touching the CDN 3425 coupling plate when
EFT/burst pulses are applied.
CDN 3425 with INA 3825 protection cover