42
NSG 3040 EMC test system
7.2.4 MONITORING screen
Monitoring window
Touch the “Monitoring” button to view EUT power input parameters, and to
control test activity and EUT power input in the event of EUT failure.
EUT Supply Voltage, EUT Supply Frequency
In case a CDN 304x series, CDN 306x series or an INA 650x is connected to the
NSG 3040, the “EUT Supply Voltage” field displays the actual EUT voltage when
the AC EUT input supply is connected and EUT power is switched “On”. When
the input supply is not connected and/or the EUT is switched off, these fields
will display NA.
The EUT Supply frequency field shows the measured frequency of the EUT
supply voltage.
Test Action at EUT Fail Input
Touch the “Test Action at EUT Fail Input” button (“Stop” in the example) to
specify the test action taken if the “EUT fail input” (on system Interface port)
is activated.
When the button is set to “Stop” and the “EUT fail input” is activated, the test
stops. The test can be restarted by pressing the Start key on the front panel.
When the button is set to “Pause” and the “EUT fail input” is activated, the test
goes into pause mode. The test can be continued by pressing the “Start” key