Functions
2.1 General
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
72
2.1.4.3
Information List
No.
Information
Type of In-
formation
Comments
301
Pow.Sys.Flt.
OUT
Power System fault
302
Fault Event
OUT
Fault Event
303
E/F Det.
OUT
E/Flt.det. in isol/comp.netw.
351
>CB Aux. L1
SP
>Circuit breaker aux. contact: Pole L1
352
>CB Aux. L2
SP
>Circuit breaker aux. contact: Pole L2
353
>CB Aux. L3
SP
>Circuit breaker aux. contact: Pole L3
356
>Manual Close
SP
>Manual close signal
357
>Blk Man. Close
SP
>Block manual close cmd. from external
361
>FAIL:Feeder VT
SP
>Failure: Feeder VT (MCB tripped)
362
>FAIL:U4 VT
SP
>Failure: Usy4 VT (MCB tripped)
366
>CB1 Pole L1
SP
>CB1 Pole L1 (for AR,CB-Test)
367
>CB1 Pole L2
SP
>CB1 Pole L2 (for AR,CB-Test)
368
>CB1 Pole L3
SP
>CB1 Pole L3 (for AR,CB-Test)
371
>CB1 Ready
SP
>CB1 READY (for AR,CB-Test)
378
>CB faulty
SP
>CB faulty
379
>CB 3p Closed
SP
>CB aux. contact 3pole Closed
380
>CB 3p Open
SP
>CB aux. contact 3pole Open
381
>1p Trip Perm
SP
>Single-phase trip permitted from ext.AR
382
>Only 1ph AR
SP
>External AR programmed for 1phase only
383
>Enable ARzones
SP
>Enable all AR Zones / Stages
385
>Lockout SET
SP
>Lockout SET
386
>Lockout RESET
SP
>Lockout RESET
410
>CB1 3p Closed
SP
>CB1 aux. 3p Closed (for AR, CB-Test)
411
>CB1 3p Open
SP
>CB1 aux. 3p Open (for AR, CB-Test)
501
Relay PICKUP
OUT
Relay PICKUP
502
Relay Drop Out
OUT
Relay Drop Out
503
Relay PICKUP L1
OUT
Relay PICKUP Phase L1
504
Relay PICKUP L2
OUT
Relay PICKUP Phase L2
505
Relay PICKUP L3
OUT
Relay PICKUP Phase L3
506
Relay PICKUP E
OUT
Relay PICKUP Earth
507
Relay TRIP L1
OUT
Relay TRIP command Phase L1
508
Relay TRIP L2
OUT
Relay TRIP command Phase L2
509
Relay TRIP L3
OUT
Relay TRIP command Phase L3
510
Relay CLOSE
OUT
Relay GENERAL CLOSE command
511
Relay TRIP
OUT
Relay GENERAL TRIP command
512
Relay TRIP 1pL1
OUT
Relay TRIP command - Only Phase L1
513
Relay TRIP 1pL2
OUT
Relay TRIP command - Only Phase L2
514
Relay TRIP 1pL3
OUT
Relay TRIP command - Only Phase L3
515
Relay TRIP 3ph.
OUT
Relay TRIP command Phases L123
530
LOCKOUT
IntSP
LOCKOUT is active
533
IL1 =
VI
Primary fault current IL1
534
IL2 =
VI
Primary fault current IL2
535
IL3 =
VI
Primary fault current IL3
536
Definitive TRIP
OUT
Relay Definitive TRIP
Содержание SIPROTEC
Страница 20: ...Contents SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 20 ...
Страница 351: ...Functions 2 18 Synchronism and Voltage Check optional SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 351 ...
Страница 494: ...Functions 2 27 Command Processing SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 494 ...
Страница 640: ...Technical Data 4 27 Dimensions SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 640 ...
Страница 657: ...Appendix A 2 Terminal Assignments SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 657 7SD5 W ...
Страница 754: ...Appendix A 10 Measured Values SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 754 ...
Страница 756: ...Literature SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 756 ...
Страница 768: ...Glossary SIPROTEC 7SD5 Manual C53000 G1176 C169 5 Release date 02 2011 768 ...