background image

Model: NP-24

24 Volt

Installation / Operation Manual

General Information

The NAV-PAC protects electronics from voltage spikes, power 
surges, momentary power losses, abrupt voltage changes and 
noise interference on incoming DC power to MDTs, GPS, and 
other onboard Electronics prone to memory loss or “crashes”. 
NAV-PAC is a solid state device which provides “pure” power 
to  navigation  electronics  by  performing  several  essential 
functions.

1) Voltage Spike Protection:

 Engine cranking, pump and

motor  operation  send  voltage  “spikes”  through  a  mobile
electrical  system  that  often  “bulldoze”  their  way  through
the  electronic  circuitry.  NAV-PAC  eliminates  this  ruinous
condition.

2) R.F.  Noise  Filtering:

  The  NEWMAR  NAV-PAC  contains

a four-element low-pass LC filter which provides very high
radio freqency attenuation in both positive and negative
power leads to the receiver preventing noise from adversely
affecting signal reception and related operation.

3) Back-Up Power:

 A long-life, completely sealed “Dry Battery”

pack is built-in the NAV-PAC which acts as a power reservoir
and is charged from the onboard 24 Volt power. In the event
of a drop in DC voltage due to engine cranking or  total power
interruption, the battery will maintain power to navigation
and communication equipment for a short period of time.
This is essential for preventing memory or data loss.

4) Timed Disconnect Circuit: 

This circuit prevents damage to

the internal battery from extreme discharge by disconnecting
the NAV-PAC battery approximately 15 minutes after abrupt
drop or complete loss of DC input.

5) Low  Battery  Disconnect  Circuit:

  This  circuit  prevents

damage  to  the  internal  battery  from  extreme  discharge
by  disconnecting  the  battery  whenever  battery  voltage
reaches 10.2 VDC

Materials Provided

Your NAV-PAC comes with the following materials:
(4) #8 ring lugs for 10-12 guage wire
(1) Installation/Operation Manual
Check to see that these items have been included with the
packaging. For any missing items, please contact factory.

Installation

1) After you have determined the best location in the system,
locate a flat surface close to the power line that feeds the
GPS or MDT. For best results, the NAV-PAC unit should be
within 24” of the critical electronics. The case need not be
grounded, so it is acceptable to mount the unit to wood or
metal. Securely mount the NAV-PAC.

Turn off power to the wires that will be cut or worked on by 
disconnecting  the  battery  or  shutting  off  the  appropriate 
circuit. Identify the positive and negative lead in the power 
line and cut at an appropriate location. Use the lugs supplied 
to hook up the NAV-PAC to your system.

2) Using the table below, select the proper wire size for your
installation.

AMPS* 

CABLE LENGTH (feet)

 

10’ 

    15’

0 - 10 AMPS 

     14 AWG 

12 AWG

10 - 15 AMPS 

     12 AWG 

10 AWG

*Current draw of equipment being powered.

Replace terminal block cover to prevent accidental shortings 
the terminals.

Important Installation Note: 

If thre is to be a continuous load 

on the NAV-PAC output during normal operations, the DC 
input must be a minimum of 26.8 VDC to prevent discharge
of the internal battery.

Отзывы: