Functions
7.5 Motor control
Inverter cabinet units
356
Operating Instructions, 12/2014, A5E32923362A
7.5
Motor control
7.5.1
Vector control or V/f control
Criteria for selecting either V/f control or vector control
Motors should preferably be operated in vector control.
When compared to V/f control, vector control offers the following advantages because of the
sensoress actual speed acquisition:
●
The speed is more stable for motor load changes.
●
Shorter accelerating times when the setpoint changes.
●
Acceleration and braking are possible with an adjustable maximum torque.
●
Improved protection of the motor and the driven machine as a result of the adjustable
torque limiting.
●
Full torque is possible at standstill.
It is not permissible to use vector control in the following cases
●
If the motor is too small in comparison to the inverter (the rated motor power must not be
less than one quarter of the rated inverter power).
●
If you operate several motors on one inverter.
●
If a power contactor is used between the inverter and motor, and is opened while the
motor is powered up.