![Ross Synergy 1 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/ross/synergy-1/synergy-1_maintenance-manual_1489025041.webp)
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
System Architecture • 2–17
CPU Structure
This section describes the CPU structure of the Synergy 1 switcher, in terms of which areas are
controlled by which specific microprocessors.
Effectively, the CPU structure of the Synergy 1
switcher functions as a master/slave duo-processor system, where the master processor controls high
level functionality, and delegates other tasks to slave processors.
In a Synergy 1 switcher, you have two microprocessors in the frame, plus one in the control panel.
Each microprocessor is a 50 MHz floating point DSP (TMS-320-C32, manufactured by Texas
Instruments), and each is identical — running at the same clock rate.
Processor Distribution and Functionality
Processor distribution and functionality is as follows:
•
One “
Frame Processo
r” on the
Frame Processor Board
is responsible for performing
high level functions, and issuing commands to the MLE processor.
This processor
manages all serial channels to and from the frame, and manages communications with
all other peripheral devices connected to the frame. In addition, it manages
communications with the control panel, and in the case of the
Synergy 100 Control
Panel
, communicates to the
Control Panel Processor
which LEDs to turn on and off
and which text to write in the various displays on the panel.
The
Frame Processor
also controls the Ultimatte
™
Insider Board, the Dual Aspectizer
®
Board and non-MLE functions, including all
Aux Bus
functions, and all crosspoint
switching.
•
One “
MLE Processor
” on the
Frame Processor Board
processes high-level
information that pertains to the current state and specific commands issued on the MLE.
This high level information includes which functions are enabled or disabled, and what
configurations have been set up by the user on the control panel.
The
MLE Processor
translates that information, and sets the required bits in the hardware to complete the
command request.
Following are several examples:
~
If you press
WIPE
in the MLE and select the circle wipe in the
Pattern Control
Group
, that information goes to the
Frame Processor
— which in turn tells the
MLE Processor
that a circle wipe has been requested.
The
MLE Processor
then
draws the proper tables required to make the image.
~
If you pull the
Fader
from Program to Preset, the
Frame Processor
receives that
information and analyses how it affects the high level structures within the switcher
— e.g., which buses are moving, what type of effect has been requested (Dissolve,
Wipe, DVE, etc.).
The
Frame Processor
then passes the current state of a particular
field to the MLE Processor, which then writes the effect’s specific values to the
video processing circuitry.
~
If you press the
AUTO TRANS
button, that command goes from the control panel
to the Frame Processor, which in turn keeps track of which state the transition is in.
Commands are then issued to the
MLE Processor
to perform the transition at (for
example) 4% in one field, 8% in the next field — until complete.
The MLE
Processor in turn
does not
process the video itself, but rather issues commands to
the hardware on the
Frame Processor Board
to set the mixer to the requested ratio
and manipulate the pixels accordingly.
Содержание Synergy 1
Страница 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Страница 10: ......
Страница 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Страница 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...