9–6 • Calibration and Diagnostics
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
7. To adjust the brightness of the red LEDs under the panel buttons:
•
Press
3. Red Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
8. To adjust the brightness of the orange LEDs under the panel buttons:
•
Press
4. Orange Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
9. To adjust the brightness of the green LEDs under the panel buttons:
•
Press
5. Green Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
10. To adjust the brightness of the red LEDs under the secret-til-lit on-air and bus indicators:
•
Press
6. Red Non-Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
11. To adjust the brightness of the orange LEDs under the secret-til-lit on-air and bus
indicators:
•
Press
7. Orange Non-Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
12. To adjust the brightness of the green LEDs under the secret-til-lit on-air and bus
indicators:
•
Press
8. Green Non-Button LED Brightness
.
•
Brightness is adjusted by rotating
any
of the knobs on the panel.
13. To exit
Calibration Mode
:
•
Press any button on the lower portion of the panel. In the four-character displays
across the top of the panel, you will receive a message asking you if you want to
save the calibration.
~
To return the switcher to normal operating mode without accepting the newly
calibrated controls, press
SEL
in the
System Control
Group
.
~
To complete the calibration and return the switcher to normal operating mode,
press
SEL
in the
Mattes
Group
.
This completes the procedure to calibrate the analog controls of the Synergy 100 switcher.
Notes on Saving a Calibration
On rare occasions, if you choose to save the calibration, the new settings fail to save correctly. If this
occurs, a message will appear in the display area informing you of this. In addition, the
SEL
buttons
in the
Mattes
and
System Control
groups will light. Press either of these buttons to confirm receiving
the warning.
You can then attempt to save the settings a second time simply by re-entering Calibration Mode (as
per Step 1), and then exiting it. You will again be asked if you wish to save the calibration, to which
you can select
Yes
in the
Mattes
Group
.
Содержание Synergy 1
Страница 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Страница 10: ......
Страница 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Страница 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...