![Ross Synergy 1 Скачать руководство пользователя страница 167](http://html1.mh-extra.com/html/ross/synergy-1/synergy-1_maintenance-manual_1489025167.webp)
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
Calibration and Diagnostics • 9–25
4. Press and hold down the following three buttons to exit the panel Diagnostic Mode:
•
SEL
in the
Effects Control
Group
•
SEL
in the
Mattes
Group
•
SEL
in the
System Control
Group
This completes the procedure to test the potentiometers on the Synergy 100 panel. If you are unsure
about the results of the test, or think that the results are incorrect, contact Ross Video Technical
Support.
Fader Test
The
Fader Test
allows you to test the MLE fader on the Synergy 100 panel.
Use the following procedure to test the fader.
1. Press and hold down the following three buttons at once:
•
SEL
in the
Effects Control
Group
•
SEL
in the
Mattes
Group
•
SEL
in the
System Control
Group
A message will scroll across the 3 four-character displays in the
Effects Control
,
Mattes
, and
System Control
groups. The message advises you that the control panel is
in Diagnostic Mode. This message will continue to scroll until a knob, button, the fader,
or the joystick is disturbed.
2. Test the fader on the Synergy 100 control panel as follows:
•
Move the fader to the upper stop. The zinger next to the fader will increase until all
of the segments are lit.
•
Move the fader to the lower stop. The zinger next to the fader will decrease until
none of the segments are lit.
3. Verify the information that is displayed in the 3 four-character displays as follows:
•
In the
Effects Control
Group
,
Fadr
appears in the display.
•
In the
Mattes
Group
, a range of numerical values appears in the display.
•
In the
System Control
Group
,
Fadr
appears in the display.
•
In addition, the LEDs in the
Transition Progress Bar
will light.
4. Press and hold down the following three buttons to exit the panel Diagnostic Mode:
•
SEL
in the
Effects Control
Group
•
SEL
in the
Mattes
Group
•
SEL
in the
System Control
Group
This completes the procedure to test the fader on the Synergy 100 control panel. If you are unsure
about the results of the test, or think that the results are incorrect, contact Ross Video Technical
Support.
Содержание Synergy 1
Страница 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Страница 10: ......
Страница 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Страница 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...