8–12 • Power Supplies
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
Replacing a Synergy Frame Power Supply Fan
This section provides instructions for replacing a failed fan in the Synergy 1 frame. A fan failure
may
be indicated by the
FRAME
LED on the Synergy 1 control panel.
Synergy 1 Control Panel — Power Fail LEDs
If the
FRAME
LED is lit, it indicates that there is a fault with the Synergy 1 frame power supply or
fan. If the fan has failed, the
FAN FAIL
LED on the Synergy 1 frame will be lit.
Replacing a Synergy Frame Power Supply Fan
Use the following procedure to change a failed Synergy frame power supply:
1. As a first step in troubleshooting, with power on, look at the power supply indicators on
the front of the frame. If the
FAN FAIL
LED is lit, it indicates that the fan is drawing too
much current, or has stopped turning.
2. Turn off the frame power switch and unplug the AC power cord from the AC outlet.
3. To gain access to the power supply fan, you must first remove the power supply tray.
Loosen the screws on the power supply lock down plate so that the plate slides up and
down easily. Use the diagram on page 7-9 for reference.
4. Remove the power supply tray as follows:
•
While holding the lock down plate in the up position, grasp the handle of the power
supply tray and remove it from the Synergy frame.
•
Set it aside on a clean, flat, static-free surface. Note that the tray does not have a
protective cover.
5. If you have access to the top plate of the Synergy 1 frame, loosen and remove the 17
screws. Set the top plate aside. This step will allow easier access to the power supply
fan, which is attached to the motherboard, located behind the power supply. Use the
diagram on page 8–13 for reference.
Warning
Hazardous
Voltages
Hazardous voltages are present inside the frame power supply housing.
This procedure should be performed by qualified service personnel
only. To reduce the risk of electric shock, do not perform any servicing
unless you are qualified to do so.
Caution
Observe all static discharge precautions.
POWER FAIL
PANEL
FRAME
Содержание Synergy 1
Страница 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Страница 10: ......
Страница 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Страница 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Страница 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...