Manual - TC.P Quadro
Technical data
2016-08-05
39/330
V04.52
3
3.1.7.1. RS-232 interface
– X301
Task of the interface X301
Calibration or parameterisation and control of the power supply via a
PC using:
TopContol software
Customer-specific software
Pin definition
for the interface X301: see chapter 3.2.4.9, page 67
RS-232 (standard)
Electrical level
RS-232/V.24
Baud rate/parity
start bits/data bits/stop bits
38400 Baud/none
1/8 /1
Isolation in relation to
controller and earth
125 V
Connector
D-Sub, 9-pin, front side
Table 24
Information on the interface X301 (RS-232).
3.1.7.2. Analogue and digital inputs and outputs
– X105
Task, interface X105
Set value specification (U, I, P, R
i
),
actual value output (U, I)
Digital remote control
Safety circuit interlock
Pin definition
for the interface X105: see chapter 3.2.4.7, page 64
Analogue inputs
Configuration
Quantity 4, can be configured to a certain extent, sin-
gle ended
Input voltage range
0
– 10 V
DC
Input impedance
20 k
Ω
Reference ground
Common for all analogue inputs
Isolation in relation to
controller and earth
125 V
Physical connections
On X105: pin 2, 3, 14, 15
Table 25
Analogue inputs on the interface X105.
Further information: chapter 3.3.3.2, page 74.