Manual - TC.P Quadro
TopControl application
2016-08-05
218/330
V04.52
6
Control group
2
1
3
4
5
6
7
8
9
Fig. 129
“Control” group on the <SCOPE> tab and its submenus.
“Control” group – parameters
1
<Start analyse> <Stop analyse>,
button
<Start analyse> Starts the recording process
Button changes to <stop analyse>
TopControl waits for a trigger event,
see “Trigger” group Table 131, page 221.
<Stop analyse> Stops the recording process
Button changes to <Start analyse>
2
<Update data>,
button
Starts the transfer and indication of the data recorded from the TopCon power
supply to the TopControl application.
3
<Options...>,
button
Opens the “SCOPE option” window with automation options.
Meaning of the check boxes if they are selected:
“Auto upload...” Transfer the data immediately from the
TopCon power supply to the TopControl application.
“Auto restart...” Recording is repeated immediately.
Optional restriction: only with trigger set
“Hide reference channels...”
The related reference signal for deactivated signal channel
is hidden.
“Reset zoom after up loading data...”
Indication is reset when new data are uploaded.
4
<File>,
button
Opens the submenu for editing
-5-, -6-, -7-, -8-, -9-.