Manual - TC.P Quadro
8) Internal (AD overrange 1)
2016-08-05
289/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
9-8
87
System voltage
overrange
AD converter value of the RMB volt-
age measurement exceeds upper
limit.
Overvoltage
After consultation with the manufacturer, the error
can be disabled if necessary.
9-9
88
System current
overrange
AD converter of the RMB current
measurement exceeds upper limit.
Overcurrent
See above, error 21)
9-9
88
System current
overrange
AD converter of the RMB current
measurement exceeds upper limit.
Overcurrent
After consultation with the manufacturer, the error
can be disabled if necessary.
9-10
89
DC link voltage
overrange
AD converter value of the DC link
voltage measurement exceeds upper
limit.
Overvoltage
See above, error 4A)
9-11
8A
Primary current
overrange
AD converter value of the primary
current (Iprim) measurement ex-
ceeds upper limit.
Overcurrent
See above, error 22)
9-13
8C
QBottom voltage
overrange
AD converter value of the QBottom
voltage measurement exceeds upper
limit.
Overvoltage
Increase the controller parameters.