Manual - TC.P Quadro
TopControl application
2016-08-05
216/330
V04.52
6
Reference values group
– “Ref.values”
siCTR_Ref
ImoduleAfterLimits
Module current reference value
for the module controller
In single device operation:
≙
RefIsystem after ramp and in-
ternal resistance correction
Value range:
0
– 4000; (4000
≙
Maximum current)
Device role:
Valid for master
siCTR_RefIsystem
System current reference value
(set value)
Value range:
0
– 4000;
Single dev. operation: 4000
≙
Nominal device current
Multi-unit operation:
4000
≙
Nominal system current
Reference value via analogue, RS-232, HMI/RCU interface
Device role:
Valid for master
siCTR_Ref
PmoduleAfterLimits
Voltage reference value for the module controller
Single dev. operation:
≙
RefPsystem after ramp
and internal resistance correction
Value range:
0
– 4000; (4000
≙ Maximum current
)
Device role:
Valid for master
siCTR_RefPsystem
Voltage reference value for the module controller
Value range:
0
– 4000;
Single dev. operation:
4000
≙
Nominal device
power
Multi-unit operation:
4000
≙
Nominal system power
Reference value via analogue, RS-232, HMI/RCU interface
Device role:
Valid for master
siCTR_Ref
UmoduleAfterLimits
Module voltage reference value
for the module controller
Single dev. operation:
≙
RefUsystem after ramp and
internal resistance correction
Value range:
0
– 4000;
(4000
≙ Maximum voltage
)
Device role:
Valid for master
siCTR_RefUsystem
System voltage reference value
(set value)
Value range:
0
– 4000;
Single dev. operation: 4000
≙
Nominal device voltage
Multi-unit operation:
4000
≙ System
nominal voltage
Reference value Via analogue, RS-232, HMI/RCU interface
Device role:
Valid for master
Table 127 Description of the reference values that are allocate
d to the “Ref.values” group (set